Skip Navigation
Michael R. Flynn1,* and Pam Susi2
1Department of Environmental Sciences and Engineering, University of North Carolina, Chapel Hill, NC 27599-7431, USA
2Center for Construction Research and Training, 8484 Georgia Avenue, Suite 1000, Silver Spring, MD 20910, USA ?* Author to whom correspondence should be addressed. Tel: +919-966-3473; fax: +919-966-7911; e-mail: Mike_flynn{at}unc.edu Received November 18, 2011. Accepted January 16, 2012. Arc welding is a common unit operation in the construction industry, where frequent changes in location and welding position make it more difficult to control fume exposures than in industries where fixed locations are the norm. Welders may be exposed to a variety of toxic airborne contaminants including manganese (Mn) and hexavalent chromium (CrVI). Local exhaust ventilation (LEV) is a well-known engineering control for welding fumes but has not been adopted widely in the construction industry. This literature review presents data on the performance of a variety of LEV systems for welding fume control from the construction (five references), shipyard (five references), and other industries. The studies indicate that LEV can reduce fume exposures to total particulate, Mn, and CrVI to levels below currently relevant standards. Field studies suggest that 40–50% or more reduction in exposure is possible with portable or fixed LEV systems relative to natural ventilation but that correct positioning of the hood and adequate exhaust flow rates are essential. Successful implementation of extraction guns for gas metal arc welding (GMAW) and flux core arc welding has been demonstrated, indicating that a successful balance between extraction airflow and shielding gas requirements is possible. Work practices are an important part of achieving successful control of fume exposures; in particular, positioning the hood close to the arc, checking exhaust flow rates, and avoiding the plume. Further research is needed on hood size effects for controlling welding fume with portable LEV systems and identifying and overcoming barriers to LEV use in construction.
© The Author 2012. Published by Oxford University Press on behalf of the British Occupational Hygiene SocietyThis Article
Ann Occup Hyg (2012) 56 (7): 764-776. doi: 10.1093/annhyg/mes018 First published online: March 29, 2012 Current Issue
Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.
View the original article here
0 comments:
Post a Comment